In this document we use to refer to the name of the database system you would like to use. Valid values for are: 'mysql' - The MySQL database system 'sqlite' - The SQLite database system 'pgsql' - The PostgreSQL database system Prerequisites ============= Required: - odb http://www.codesynthesis.com/products/odb/ - libodb http://www.codesynthesis.com/products/odb/ - libodb-tracer http://www.codesynthesis.com/products/odb/ - libodb- http://www.codesynthesis.com/products/odb/ Optional: - libodb-boost http://www.codesynthesis.com/products/odb/ - Boost http://www.boost.org - libodb-qt http://www.codesynthesis.com/products/odb/ - Qt http://qt.nokia.com Building on UNIX ================ The following build instructions are for the Linux/UNIX/Mac OS X operating systems as well as for Cygwin and MinGW on Windows. The standard autotools-based build system is used on these platforms. After unpacking the source code archive, change to the odb-tests package directory (referred to as odb-tests/ from now on) and run the configure script, for example: ./configure --with-database To see the available configuration options run configure with --help: ./configure --help The required --database option specifies the database system you would like to use. The configure script expects the directory where the ODB compiler binary is installed to be in the executable search path (the PATH environment variable). If that's not the case, you can use the ODB configure variable to specify the path to the ODB compiler, for example: ./configure ODB=/opt/odb/bin/odb If the ODB compiler is not installed and you would like to run it from its build directory instead, you can use the --with-odb configure option to specify the build directory, for example: ./configure --with-odb=/tmp/odb The configure script also expects the libodb, libodb-tracer, and libodb- headers and libraries to be installed in a directory where the C++ compiler and linker will search for them by default (normally /usr and /usr/local). If these libraries are installed in other directories, you can use the CPPFLAGS and LDFLAGS configure variables to specify their locations, for example: ./configure CPPFLAGS=-I/opt/libodb/include LDFLAGS=-L/opt/libodb/lib If these libraries are not installed and you would like to use their build directories instead, you can use the --with-libodb, --with-libodb-tracer, and --with-libodb- configure options to specify their locations, for example: ./configure --with-libodb=/tmp/libodb If you would also like to build the boost profile tests, then the configure script should be able to find headers and libraries for libodb-boost and Boost. Similarly, if you would like to build the qt profile tests, then the configure script should be able to find headers and libraries for libodb-qt and Qt. The same mechanisms as described above can be used to specify locations of these libraries if they cannot be discovered automatically. For each value the configure script has a set of options in the form --with--* that allow you to specify various database system parameters, such as the login name, password, and database name, that should be used when running the tests. Run configure with --help to see the available options for your database. As another example, the following configure command uses the specified C++ compiler and compiles with optimization and without debug information: ./configure CXX=g++-4.5 CXXFLAGS=-O3 Once configuration is complete, run make to build the tests: make Once the build is completed successfully you can run the tests using the check target: make check Building on Windows =================== The following build instructions are for Windows using Microsoft Visual Studio. If you would like to build odb-tests with GCC either using Cygwin or MinGW, refer to the "Building on UNIX" section above. The standard Visual Studio project and solution files are used on this platform. The provided project files expect the directory where the ODB compiler binary is installed to be in the executable search path (the PATH environment variable). They also expect the libodb, libodb-tracer, and libodb- header and import library directories to be in the VC++ Directories Include and Library search lists. See the INSTALL files in the ODB library packages for more information on how to setup their VC++ Directories. If you would also like to build the boost profile tests, then the header and import library directories for libodb-boost and Boost must be in the VC++ Directories Include and Library search lists. Similarly, if you would like to build the qt profile tests, then the header and import library directories for libodb-qt and Qt must be in the VC++ Directories Include and Library search lists. See the INSTALL files in the ODB library packages for more information on how to setup their VC++ Directories. For Boost and Qt, refer to their documentation. There are two ways to build the tests with Visual Studio. After unpacking the source code archive, you can manually open solution files located in the tracer\, common\, \, boost\common\, boost\\, qt\common\, and qt\\ directories in the odb-tests package directory (referred to as odb-tests\ from now on). In the tracer\ directory the solution file is named tracer-vc.sln. In the common\, boost\common\, and qt\common\ directories they are named common--vc.sln. And in the \, boost\\, and qt\ directories they are named -vc.sln. Here is the version of Visual Studio that you are using. Once each solution is open, select the desired build configuration (Debug or Release) and platform (Win32 or x64) and build the solution. Alternatively, you can use the build.bat batch files located in the odb-tests\, odb-tests\boost\, and odb-tests\qt\ directories to build all the solutions, for all the configurations and for all the platforms automatically. The build.bat file has the following command line interface: build.bat [/Build|/Clean|/Rebuild] Where is the version of Visual Studio that you are using, is the desired configuration (e.g., Debug or Release), and is the desired platform (e.g., Win32 or x64). For and arguments you can specify several configurations or platforms. You can also use the 'all' value to build all configurations and/or all platforms. If no action is specified, the default is /Build. Once the build is completed successfully, you can run all the tests using the test.bat batch file located in the odb-tests\ directory. Before you can run test.bat, you may need to adjust the database system parameters, such as the login name, password, and database name, that should be used when running the tests. To do this, edit the .options and -driver.bat files located in the odb-tests\ directory. Once this is, done you can run the tests by executing the following command from the command prompt: test.bat